Difference between revisions of "AXY:MC-Basic:group.PROFILERTYPE"
m |
|||
| Line 13: | Line 13: | ||
* -1 - profile type is defined by the [[Axystems:MC-Basic:axis.SMOOTHFACTOR|SmoothFactor]] | * -1 - profile type is defined by the [[Axystems:MC-Basic:axis.SMOOTHFACTOR|SmoothFactor]] | ||
| − | * 0 – Velocity trapeze (VT) <br> | + | * 0 – Velocity based Velocity trapeze (VT) <br> |
* 1 – Velocity based Sine acceleration (SA) <br> | * 1 – Velocity based Sine acceleration (SA) <br> | ||
* 2 – Time based trapeze acceleration (TA) or velocity trapeze (VT) | * 2 – Time based trapeze acceleration (TA) or velocity trapeze (VT) | ||
| Line 26: | Line 26: | ||
|RANGE= | |RANGE= | ||
| − | + | -1-3 | |
|UNITS= | |UNITS= | ||
| Line 32: | Line 32: | ||
|DEFAULT= | |DEFAULT= | ||
| − | 1 | + | -1 |
|SCOPE= | |SCOPE= | ||
Revision as of 08:10, 5 June 2011
Defines the profiler-type used in the motion.
- -1 - profile type is defined by the SmoothFactor
- 0 – Velocity based Velocity trapeze (VT)
- 1 – Velocity based Sine acceleration (SA)
- 2 – Time based trapeze acceleration (TA) or velocity trapeze (VT)
- 3 - Constant Velocity profile (one sample acceleration and one sample deceleration)
Axystems:PrfType vs SmoothFactor
Short form
PrfType
Syntax
<group>.profilertype = <numeric expression>
Availability
4.5.25
Type
Long
Range
-1-3
Default
-1
Scope
Configuration, Task, Terminal
Limitations
Modal/Nodal