Difference between revisions of "AXY:MC-Basic:group.BLENDINGFACTORPREVIOUS"
Line 14: | Line 14: | ||
* 0% – blending of second movement started from the beginning of the first one . | * 0% – blending of second movement started from the beginning of the first one . | ||
* 100% – blending of second movement started from the end of the first one (NO BLENDING) . | * 100% – blending of second movement started from the end of the first one (NO BLENDING) . | ||
+ | |||
+ | For more description see also: [[Axystems:BlendingBehavior | Blending Behavior]] | ||
|TYPE= | |TYPE= |
Revision as of 08:44, 13 April 2011
Percentage of the movement’s length that will be not blended with the next movement.
- 0% – blending of second movement started from the beginning of the first one .
- 100% – blending of second movement started from the end of the first one (NO BLENDING) .
For more description see also: Blending Behavior
Short form
BFPrev
Syntax
?<group>.BlendingFactorPrevious
<group>. BlendingFactorPrevious = <value>
Type
Double
Range
-1 to 100
Units
Percents of the segments length
Default
-1 (not active)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid , Modal/Nodal
Examples
G1.BlendingFactorPrevious= 10
?G1.BlendingFactorPrevious