Difference between revisions of "MC-Basic:axis.COMPPOSITIONFEEDBACK"
(Created page with '{{MC-Basic |SHORT FORM= <''axis''>.CompPFB |SYNTAX= ? <''axis''>.CompPositionFeedback |AVAILABILITY= Versions 3.6.20 and higher |DESCRIPTION= The Actual Corrected Position fee…') |
m (1 revision) |
(No difference)
|
Revision as of 16:10, 13 December 2010
The Actual Corrected Position feedback query .This property returns the position feedback generated by the motion profiler after the correction value added to it. When no correction is used (i.e all the comp tables involves the axis as its target is inactive) then this value would be identical to the Axis.Pfb.
Short form
<axis>.CompPFB
Syntax
? <axis>.CompPositionFeedback
Availability
Versions 3.6.20 and higher
Type
Double
Range
+/- MaxDouble
Units
User Axis position units as given by <Axis>.PositionFactor
Scope
Task and Terminal
Limitations
Read Only
Examples
<comp>.SourceData[1][15] = 120.0 ‘position on axis
<comp>.TargetData[1][15] = 0.125 ‘correction value regarding SourceData position
Move <axis> 120.0
Print <axis>.Pfb
--> 120.0 ‘ (it’s the “expected user value”)
Print <axis>.CompPfb
--> 120.125 ‘(it’s the “real value”)