Difference between revisions of "MC-Basic:pls.PLSHYSTERESIS"
(Created page with '{{MC-Basic |SHORT FORM= ''<pls>''.Phys |SYNTAX= ''<pls>''.PlsHysteresis = ''<hysteresis value>''<br> ?''<pls>''.PlsHysteresis |AVAILABILITY= All versions |DESCRIPTION= Set o…') |
m (1 revision) |
(No difference)
|
Revision as of 16:10, 13 December 2010
Set or query the hysteresis level of the PLS. Hysteresis is used to prevent a PLS from being fired repeatedly when the axis is at the defined position.
Short form
<pls>.Phys
Syntax
<pls>.PlsHysteresis = <hysteresis value>
?<pls>.PlsHysteresis
Availability
All versions
Type
Double
Range
Greater than 0
Units
User axis position units, as given by <axis>.POSITIONFACTOR
Default
0
Scope
Configuration, Task or Terminal
Limitations
The hysteresis may be set only when the PLS is disabled.
Examples
PLS1.Phys = 10