This property sets the number of cycles for which the CAM table is to be executed. A CAM table is repeated when the master passes the end of the table and the number of cycles has a value greater than 1. Setting the number of cycles to the value -1 enables the table to be repeated continually. The number of cycles is changed while camming is enagaged.
Short form
Cyc
Syntax
<cam>.Cycle = <number of cycles>
?<cam>.Cycle
Availability
All versions
Type
Long
Range
-1, 1 to MaxLong
Default
1
Scope
Configuration, Task or Terminal
Examples
Cam1.Cycle = -1