Defines the torque-error collision procedure. If the TE > TEMAX axis is disabled after it is stopped by the stop profile defined by TorqueErrorStopType, according to values of TorqueErrorDisableType:
0 normal
1 high-power
2 TBD
Short form
<axis>.TorqueErrorDisableType
Syntax
?<axis>. TorqueErrorDisableType
Availability
AMCS 4.5.x
Type
Integer
Range
0 to 2
Default
0
Scope
Configuration, Task or Terminal
Limitations
Read/Write only, Modal Only
Examples
?A1.TorqueErrroDisableType