Language: | English • 中文(简体) |
---|
DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases? -single axis movement,? or group movement from type Move or Circle.
Short form
<axis>.DecStop
Syntax
<axis>.DecelerationStop = <value>
Type
Double
Read/Write
Range
0.01 to Max Double
Units
Acceleration user units
Default
1000
Scope
Terminal or task
Limitations
Modal Only.
Examples
A1.DecStop = 1000