This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Lower 16 bits reflect drive status word (object 0x6041/0). <br>
 
This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Lower 16 bits reflect drive status word (object 0x6041/0). <br>
You can find more information [http://servotronix.com/html/Help_CDHD_EN/HTML/home.htm#!Documents/6041hstatusword.htm HERE]
+
You can find more information at the [http://servotronix.com/html/Help_CDHD_EN/HTML/home.htm#!Documents/6041hstatusword.htm CDHD manual] or at the [http://www.servotronix.com/html/stepIM_Help/HTML/#!Documents/6041hstatusword.htm stepIM manual]
 
<br>
 
<br>
 
{{{!}}class = "wikitable" style="text-align: left"
 
{{{!}}class = "wikitable" style="text-align: left"

Revision as of 12:41, 26 September 2017

Language: [[::MC-Basic:axis.DRIVESTATUS|English]]  • [[::MC-Basic:axis.DRIVESTATUS/zh-hans|中文(简体)‎]]

This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Lower 16 bits reflect drive status word (object 0x6041/0).
You can find more information at the CDHD manual or at the stepIM manual

Bit - DS402 Bit - MC Basic Description Values
0 14 & 15 Ready to switch on
1 14 & 15 Switched on
2 14 & 15 Operation enabled
3 13 Fault
4 14 & 15 Voltage enabled 0 - High voltage applied
1 - High voltage not applied
7 12 Warning NOTE - warning isn't an error
11 11 Internal limit active 0 - activated
1 - not activated
12 3 Operation mode specific
20 20 Data invalid 0 - motion bus data is valid
1 - motion bus data is not valid - corrupted or missing
22 22 Limit Switch in Drive (from version 0.4.17.2) 0 - Limit switch is not active
1 - Limit switch is active


Legacy SERCOS - SERCOS only

Bit Description Values
0 AHS 0 or 1 - Service transport handshake of the drive
1 Busy 0 - Step finished, ready for new step
1 - Step in progress, new step not allowed
2 Error in service channel
3 Status command value processing 0 - Drive ignores the command values
(e.g., during Halt drive, drive controlled functions, programmed delay times)
1 - Drive follows the command values
4 Parameterization levels (PL1, PL2) 0 - PL1 and PL2 not active.
1 - PL1 or PL2 active.
5 Procedure command change bit
6 Real-time status bit 1
7 Real-time status bit 2
8, 9, 10 Actual operation mode 0 0 0 - Primary operation mode (defined by S-0-0032)
0 0 1 - Secondary operation mode 1 (defined by IDN 33)
0 1 0 - Secondary operation mode 2 (defined by IDN 34)
0 1 1 - Secondary operation mode 3 (defined by IDN 35)
11 Change bit for C3D
12 Change bit for C2D
13 Drive Shutdown - Error in C1D
14 Drive status 0 - disabled
1 - enabled
15 Drive high power 0 - high power off
1 - high power on

Short form

<axis>.DStat

Syntax

?<axis>.DriveStatus

Availability

All versions

Type

Long

Scope

Configuration, Task or Terminal

Limitations

Read only.
SERCOS: Valid only in SERCOS communication phase 4.
EtherCAT: Valid only in OP mode.
EtherCAT and CAN: Limit switch state is reflected in bit #22.

Bits 0,1,2,4,5,6,7,8,9,10,11,12 are applicable only to SERCOS
EtherCAT/CANopen:
Bit 13: reflects state of bit #4 of status word (object 0x6041 subindex 0) and only if that object is mapped to PDO.

Examples

?a1.dstat

If (a1.dstat band 2^14) Then                        ‘Check whether the drive is enabled

See Also