This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions. <br>
 
This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions. <br>
 
<br>
 
<br>
{{{!}}class = "wikitable" style="text-align: center"
+
{{{!}}class = "wikitable" style="text-align: left"
 
{{!}}'''Bit'''
 
{{!}}'''Bit'''
 
{{!}}'''Description '''
 
{{!}}'''Description '''
Line 34: Line 34:
  
 
==='''Legacy SERCOS - <small><small>SERCOS only</small></small>'''===  
 
==='''Legacy SERCOS - <small><small>SERCOS only</small></small>'''===  
{{{!}} class = "wikitable" style="text-align: center"
+
{{{!}} class = "wikitable" style="text-align: left"
 
{{!}}'''Bit'''
 
{{!}}'''Bit'''
 
{{!}}'''Description '''
 
{{!}}'''Description '''

Revision as of 12:55, 24 September 2017

Language: [[::MC-Basic:axis.DRIVESTATUS|English]]  • [[::MC-Basic:axis.DRIVESTATUS/zh-hans|中文(简体)‎]]

This read-only property queries the drive status. The drive status is returned every bus cycle and comprises 32 bits. Following are the most important bit descriptions.

Bit Description Values
15 CAN and EtherCAT
Reflect drive status object 0x6041/0 if mapped to PDO
22 Limit Switch in Drive (from version 0.4.17.2) 0 - Limit switch is not active
1 - Limit switch is active
21 Data invalid 0 - motion bus data is valid
1 - motion bus data is not valid - corrupted or missing


Legacy SERCOS - SERCOS only

Bit Description Values
0 AHS 0 or 1 - Service transport handshake of the drive
1 Busy 0 - Step finished, ready for new step
1 - Step in progress, new step not allowed
2 Error in service channel
3 Status command value processing 0 - Drive ignores the command values
(e.g., during Halt drive, drive controlled functions, programmed delay times)
1 - Drive follows the command values
4 Parameterization levels (PL1, PL2) 0 - PL1 and PL2 not active.
1 - PL1 or PL2 active.
5 Procedure command change bit
6 Real-time status bit 1
7 Real-time status bit 2
8, 9, 10 Actual operation mode 0 0 0 - Primary operation mode (defined by S-0-0032)
0 0 1 - Secondary operation mode 1 (defined by IDN 33)
0 1 0 - Secondary operation mode 2 (defined by IDN 34)
0 1 1 - Secondary operation mode 3 (defined by IDN 35)
11 Change bit for C3D
12 Change bit for C2D
13 Drive Shutdown - Error in C1D
14 Drive status 0 - disabled
1 - enabled
15 Drive high power 0 - high power off
1 - high power on

Short form

<axis>.DStat

Syntax

?<axis>.DriveStatus

Availability

All versions

Type

Long

Scope

Configuration, Task or Terminal

Limitations

Read only.
SERCOS: Valid only in SERCOS communication phase 4.
EtherCAT: Valid only in OP mode.
EtherCAT and CAN: Limit switch state is reflected in bit #22.

Bits 0,1,2,4,5,6,7,8,9,10,11,12 are applicable only to SERCOS
EtherCAT/CANopen:
Bit 13: reflects state of bit #4 of status word (object 0x6041 subindex 0) and only if that object is mapped to PDO.

Examples

?a1.dstat

If (a1.dstat band 2^14) Then                        ‘Check whether the drive is enabled

See Also