Defines the desync profile of the translational moving frame componenet, robot motion profile from the moment of starting desynchronization from the moving frame (slave=0) until its complete disconnection (slave=0).
Syntax
<ROBOT>.AccelerationDeSyncTran = <numeric expression>
Availability
Since Version 4.0.22
Type
Double
Range
0 to MaxDouble
Units
mm/sec²
Default
100000
Scope
Configuration, Task or Terminal
Limitations
Read/Write, Modal Only
Examples
Scara.AccelerationDeSyncTran = 500