Difference between revisions of "AXY:MC-Basic:axis.ENABLE"
m (Miborich moved page Axystems:MC-Basic:axis.ENABLE to MC-Basic:axis.ENABLE: Global renaming of Axystems: namespace into (Main):) |
|
(No difference)
|
Revision as of 08:45, 22 May 2014
This property enables or disables the drive. The property encapsulates operation of drive status bit 15, and causes an active disable of the drive when set to 0. The softMC interpreter is held until the requested state is actually achieved on the drive.
When the drive is disabled, the motion controller of that axis is in a following mode, so the command follows the feedback. A message is generated by the softMC that the axis is now in following mode. Motion commands are not allowed when the drive is disabled.
0 (OFF) - Drive disable
1 (ON) - Drive enable
Short form
<axis>.En
Syntax
<axis>.Enable = <value>
?<axis>.Enable
Availability
All versions
Type
Long
Range
0 or 1
Default
0 (at power on)
Scope
Configuration, Task or Terminal
Limitations
Real axes are enabled and disabled only in SERCOS communication phase 4. Simulated axes are enabled and disabled in SERCOS communication phases 4 and 0. The SYSTEM.ENABLE flag must be ON in order for a drive to be enabled.
Examples
a1.enable = 1