In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed.
 
In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed.
  
{{Note/Important| '''THIS COMMAND IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
''<''drive''>: Long<br>
+
<''drive''>: Long<br>
''<IDN number>'': Long<br>
+
<''IDN number''>: Long<br>
 
<''value''>: Long<br>
 
<''value''>: Long<br>
''<IDN element>'': Long
+
<''IDN element''>: Long
 
<''ring''>: Long
 
<''ring''>: Long
 
<''connection''>:Long
 
<''connection''>:Long
Line 36: Line 35:
  
 
|RANGE=
 
|RANGE=
''<''drive''>: 1 to 254<br>
+
<''drive''>: 1 to 254<br>
''<IDN number>'': 1 to 65535<br>
+
<''IDN number''>: 1 to 65535<br>
''<IDN element>'': 1 to 7
+
<''IDN element''>: 1 to 7 <br>
<''ring''>:1
+
<''ring''>:1 <br>
 
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
 
<''connection''>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)
  
Line 53: Line 52:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* Write only.
+
*Write only  
* Executed only in SERCOS communication phases 2, 3 and 4.  
+
*Executed only in SERCOS communication phases 2, 3 and 4.
* The IDN must be defined.
+
*The IDN must be defined
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 11:46, 26 March 2014

This command writes the Long Type value of a specified element of an IDN to a specified drive. It is used when writing to an IDN that takes numeric values.

<element> is optional. In general, only element 7 is used (default).

This command is also used to operate a procedure command. In this case, the value 3 is written to begin the procedure, and the value 0 is written to cancel the procedure once it has completed.

Short form

WIVal

Syntax

WriteIdnValue Drive=<drive address>, Idn=<IDN number>, Value=<value>, {Element=<IDN element number>}


From Since Version 4.7.12 for SERCOS III :

WRITEIDNVALUE Drive=<drive address> IDN=<IDN number> Value=<value {,<value>}> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

All versions

Type

<drive>: Long
<IDN number>: Long
<value>: Long
<IDN element>: Long <ring>: Long <connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write only
  • Executed only in SERCOS communication phases 2, 3 and 4.
  • The IDN must be defined
  • Not supported in EtherCAT system

Examples

WriteIdnValue Drive=2 Idn=159 Value=10000       'Set PEMAX on drive

 

WIVal Drive = 1 IDN = 99 Value = 3              'Begin Reset Faults procedure

From Since Version 4.7.12 for SERCOS III :

WriteIdnValue Drive=2 Idn=159 Value=10000 Element= 7 Ring= 1 Connection= 0


See Also