Returns number of tokens (byte-codes) executed by Interpreter since its invocation.  This command is used for diagnostics, like detection of endless loops in entry station context.
       1 – Ethernet
      3 – Virtual Entry Station
       4 – Ethernet2

Syntax

? ESTokenCount

Availability

Since Version 4.5.28

Type

Long

Range

1 to 4

Scope

Configuration, Task, Terminal

Limitations

Read Only.

ESTokenCount will return error 5029 ("No such device") for inactive entry station.

Examples

-->?ESTokenCount(1)

4

-->?ESTokenCount(2)

Error:  5029, "No such device.", Task: ,ESEthern0, Line: 1, Module: Entry_Station

See Also