Difference between revisions of "AXY:MC-Basic:axis.SineWaveFreq"
m (Text replace - "AMCS FW 4.9.6" to "Since Version 4.9.6") |
|||
Line 9: | Line 9: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | Sets the desired frequency for the [[ | + | Sets the desired frequency for the [[MC-Basic:SineWave|SineWave]] motion command. |
The frequency actually used is limited by the maximal velocity, acceleration and jerk of the axis. | The frequency actually used is limited by the maximal velocity, acceleration and jerk of the axis. | ||
Line 28: | Line 28: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | * Only in combination with the [[ | + | * Only in combination with the [[MC-Basic:SineWave|SineWave]] command |
* Nodal only | * Nodal only | ||
* Write only | * Write only | ||
Line 38: | Line 38: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:SineWave|SineWave]] |
* [[Axystems:MC-Basic:group.SineWaveFreq|group.SineWaveFreq]] | * [[Axystems:MC-Basic:group.SineWaveFreq|group.SineWaveFreq]] | ||
}} | }} |
Revision as of 08:42, 22 May 2014
Sets the desired frequency for the SineWave motion command. The frequency actually used is limited by the maximal velocity, acceleration and jerk of the axis.
Syntax
SineWave <axis> <amplitude> SineWaveFreq = <frequency>
Availability
Since Version 4.9.6
Type
Double
Range
> 0
Units
Hertz [Hz]
Default
1.0 Hz
Scope
Task or Terminal
Limitations
- Only in combination with the SineWave command
- Nodal only
- Write only
Examples
SineWave ax2 300 SineWaveFreq = 4
...
Stop ax2