Defines the maximum allowed error between position command and the position feedback. the position following error (PE) is calculated every sample time and compared to maximum position error PEMAX. If it exceeds the value of PEMAX, the group is brought to an immediate stop. If the group is at rest when the error is detected, the drives in the group are disabled. For a group, the position following error is calculated as the square root of the sum of the squares of each axis’ position error. The position following error on a group is Terminaled only when the group is in motion, or as long as it is attached by a task.

Short form

<group>.PEMax

Syntax

<group>.PositionErrorMax = <value>

Availability

All versions

Type

Double

Range

0 to MaxDouble

Units

User units

Default

1e-6

Scope

Task or Terminal

Limitations

Write only

Examples

XYTable.PEMAX=0.012

?XYTable.PEMAX

See Also