Difference between revisions of "MC-Basic:axis.REALTIMECONTROLBIT"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "Available since version 4.5.18" to "Since Version 4.5.18")
m
Line 13: Line 13:
 
|DESCRIPTION=
 
|DESCRIPTION=
 
In SERCOS a realtime control bit is set to activate a function. This property is used to set a <''value''> or query a realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
 
In SERCOS a realtime control bit is set to activate a function. This property is used to set a <''value''> or query a realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
 
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
 
 
  
 
|TYPE=
 
|TYPE=
Line 25: Line 20:
 
<''value''> – 0 or 1
 
<''value''> – 0 or 1
  
''<bit_number''> – 1 or 2
+
<''bit_number''> – 1 or 2
  
 
|UNITS=
 
|UNITS=
Line 37: Line 32:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Can only be set during SERCOS communications phase 4.
+
*Can only be set during SERCOS communications phase 4
 +
*Not supported in EtherCAT system
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 12:35, 26 March 2014

In SERCOS a realtime control bit is set to activate a function. This property is used to set a <value> or query a realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.

Short form

<axis>.RTCB[ ]

Syntax

?<axis>.RTCB[<bit_number>]

<axis>.RTCB[<bit_number>] = <value>

Availability

Since Version 4.5.18

Type

Long

Range

<value> – 0 or 1

<bit_number> – 1 or 2

Scope

Configuration, Task or Terminal

Limitations

  • Can only be set during SERCOS communications phase 4
  • Not supported in EtherCAT system

Examples

?x_axis.rtcb[1]

x_axis.rtcb[2] = 1