Line 30: Line 30:
 
1 – Velocity  operation mode
 
1 – Velocity  operation mode
  
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=
Line 49: Line 47:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Engaging sys.pipemode (1 or 2) is not allowed during motion.. To leave pipemode, all axes pipemode property should be off.
+
*Engaging sys.pipemode (1 or 2) is not allowed during motion. To leave pipemode, all axes pipemode property must be off.
 +
*Read only
  
 
|EXAMPLE=
 
|EXAMPLE=

Revision as of 11:41, 26 March 2014

This property defines motion pipe mode type. Pipe mode types:

0 – Pipe mode is inactive

1 – Position pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position commands for the respective axes.

2 – Position & Velocity pipe-mode is active. Sys.HostDouble[1]…Sys.HostDouble[8] contain position and velocity commands for the respective axes.

Sys.VIn contains drive’s operation mode information.

Sys.Vin variable.defines  the Operation modes for each axis are set 0 or  1.

The valid operation modes values are :

0 – Position operation mode

1 – Velocity  operation mode

Short form

Sys.PMode

Syntax

Sys.PMode = <expression>

? Sys.PMode

Availability

Since Version 3.6.20

Type

Long

Range

0 , 1 or 2

Default

0

Scope

Config, Task or Terminal

Limitations

  • Engaging sys.pipemode (1 or 2) is not allowed during motion. To leave pipemode, all axes pipemode property must be off.
  • Read only

Examples

Sys.PMode = 1

?Sys.PMode

See Also