Revision as of 16:24, 20 March 2014
Defines minimum acceleration time, if set to 0 the whole feature is switched off.
Short form
<axis>.TAccMin
Syntax
<axis>.TAccMin=<numeric expression>
Availability
Since Version 3.7.x
Type
integer
Range
0-maxlong
Units
milliseconds
Default
0 – not active
Scope
Task, Terminal
Limitations
- Modal/Nodal
- Read/Write
Examples
Scara.timeaccmin = 500
Scara.timedecmin = 1000