Difference between revisions of "MC-Basic:axis.COMPPOSITIONFEEDBACK"
m (Text replace - "<axis>" to "<''axis''>") |
m (Text replace - "Versions 3.6.20 and higher" to "Since Version 3.6.20") |
||
Line 7: | Line 7: | ||
|AVAILABILITY= | |AVAILABILITY= | ||
− | + | Since Version 3.6.20 | |
|DESCRIPTION= | |DESCRIPTION= |
Revision as of 13:56, 20 March 2014
The Actual Corrected Position feedback query .This property returns the position feedback generated by the motion profiler after the correction value added to it. When no correction is used (i.e all the comp tables involves the axis as its target is inactive) then this value would be identical to the Axis.Pfb.
Short form
<axis>.CompPFB
Syntax
?<axis>.CompPositionFeedback
Availability
Since Version 3.6.20
Type
Double
Range
± MaxDouble
Units
User Axis position units as given by <axis>.PositionFactor
Scope
Task and Terminal
Limitations
Read Only
Examples
<comp>.SourceData[1][15] = 120.0 ‘position on axis
<comp>.TargetData[1][15] = 0.125 ‘correction value regarding SourceData position
Move <axis> 120.0
Print <axis>.Pfb
--> 120.0 ‘ (it’s the “expected user value”)
Print <axis>.CompPfb
--> 120.125 ‘(it’s the “real value”)