Difference between revisions of "MC-Basic:axis.IN1MODE"

From SoftMC-Wiki
Jump to: navigation, search
Line 2: Line 2:
 
|SHORT FORM=
 
|SHORT FORM=
  
 +
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
  
 
|SYNTAX=
 
|SYNTAX=
Line 37: Line 38:
 
Specifying an invalid value specified displays the message “Incorrect parameter value.” <br>
 
Specifying an invalid value specified displays the message “Incorrect parameter value.” <br>
 
Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.”
 
Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.”
 
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
  
 
|TYPE=
 
|TYPE=

Revision as of 11:03, 18 March 2014

Specifies the functionality of the drive digital input 1.
0 – no special function
1 – CW limit switch
2 – CCW limit switch
3 – reserved
4 – reserved
5 – reserved
6 – reserved
7 – reserved
8 – second bipolar torque limit
9 – reserved
10 – home switch
11 – reserved
12 – reserved
13 – reserved
14 – reserved
15 – reserved
16 – probe input (capture)
17 – reserved
18 – open fault relay

Two keyword values are defined:

  • “capturing” (=16)
  • “homing” (=10)

Specifying an invalid value specified displays the message “Incorrect parameter value.”
Replacing a previous functionality displays the message “Input switch might have been dedicated to another function.”

Short form

IMPORTANT.svgIMPORTANT
THIS PROPERTY IS OBSOLETE

Syntax

<axis>.In1Mode = <value>

Availability

All versions

Type

Long

Range

0 to 18

Default

Dependent on the drive

Scope

Task or Terminal

Limitations

  • Each function input may be assigned only one digital value.
  • Valid in communications phase 2 or higher.

Examples

?a1.In1Mode

a1.In1mode = homing

See Also