Difference between revisions of "MC-Basic:axis.DECELERATIONSTOP"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<axis>.''" to "<''axis''>.")
m (Text replace - "R/W" to "Read/Write")
Line 15: Line 15:
 
Double
 
Double
  
R/W
+
Read/Write
  
 
|RANGE=
 
|RANGE=

Revision as of 06:58, 19 March 2014

DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases  -single axis movement,  or group movement from type Move or Circle.

Short form

<axis>.DecStop

Syntax

<axis>.DecelerationStop = <value>

Type

Double

Read/Write

Range

0.01 to Max Double

Units

Acceleration user units

Default

1000

Scope

Terminal or task

Limitations

Modal Only.

Examples

A1.DecStop = 1000

See Also