Difference between revisions of "MC-Basic:axis.REALTIMECONTROLBIT"
m (Text replace - "''<value>''" to "<''value''>") |
m |
||
Line 6: | Line 6: | ||
?<''axis''>.RTCB[''<bit_number>''] | ?<''axis''>.RTCB[''<bit_number>''] | ||
− | <''axis''>.RTCB[''< | + | <''axis''>.RTCB[''<bit_number>''] ='' <value>'' |
|AVAILABILITY= | |AVAILABILITY= | ||
Line 12: | Line 12: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | In SERCOS | + | In SERCOS a realtime control bit is set to activate a function. This property is used to set a (<''value''>) or query a realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method. |
+ | |||
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | ||
+ | |||
+ | |||
|TYPE= | |TYPE= | ||
Line 20: | Line 23: | ||
|RANGE= | |RANGE= | ||
− | <''value''> | + | <''value''> – 0 or 1 |
− | ''<bit_number | + | ''<bit_number''> – 1 or 2 |
|UNITS= | |UNITS= |
Revision as of 10:24, 19 March 2014
In SERCOS a realtime control bit is set to activate a function. This property is used to set a (<value>) or query a realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<AXIS>.RTCB[ ]
Syntax
?<axis>.RTCB[<bit_number>]
<axis>.RTCB[<bit_number>] = <value>
Availability
Available since version 4.5.18
Type
Long
Range
<value> – 0 or 1
<bit_number> – 1 or 2
Scope
Configuration, Task or Terminal
Limitations
Can only be set during SERCOS communications phase 4.
Examples
?x_axis.rtcb[1]
x_axis.rtcb[2] = 1