Difference between revisions of "MC-Basic:axis.CAPTURESOURCE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<value>''" to "<''value''>")
m (Text replace - "<axis>" to "<''axis''>")
Line 1: Line 1:
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
''<axis>.CapSrc''
+
''<''axis''>.CapSrc''
  
 
|SYNTAX=
 
|SYNTAX=

Revision as of 11:18, 19 March 2014

This property is used to set the source is used as the position capture. This property takes the values 0 - for the motor position capture or 1 – for  the external position capture .

IMPORTANT.svgIMPORTANT
THIS PROPERTY IS OBSOLETE

Short form

<axis>.CapSrc

Syntax

<axis>.CaptureSource = <value>

Availability

All versions

Type

Long

Range

0 – motor

1 - external source

Default

0

Scope

Configuration, Task or Terminal

Limitations

Can be set in SERCOS communications phase 2 . Read only in communications phase 4 .

Examples

ser.phase=0

a1.CaptureSource = 1                     ' Capture external position

See Also