Revision as of 15:41, 17 March 2014

Percentage of the movement length that will be not blended with the next movement.

  • 0% – blending of second movement started from the beginning of the first one.
  • 100% – blending of second movement started from the end of the first one (no blending).

Short form

BFPrev

Syntax

?<Axis>.BlendingFactorPrevious

<Axis>. BlendingFactorPrevious = <value>

Type

Double

Range

-1 to 100

Units

Percents of the segments length

Default

-1 (not active)

Scope

Task or Terminal

Limitations

Mixed profiler types are not valid, Modal/Nodal

Examples

Ax1.BlendingFactorPrevious= 10

?Ax1.BlendingFactorPrevious

See Also