Difference between revisions of "AXY:MC-Basic:axis.BLENDINGFACTORPREVIOUS"
m (Text replace - "''<value>''" to "<''value''>") |
|||
Line 11: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | Percentage of the | + | Percentage of the movement length that will be not blended with the next movement. |
− | * 0% – blending of second movement started from the beginning of the first one . | + | * 0% – blending of second movement started from the beginning of the first one. |
− | * 100% – blending of second movement started from the end of the first one ( | + | * 100% – blending of second movement started from the end of the first one (no blending). |
|TYPE= | |TYPE= | ||
Line 31: | Line 31: | ||
|LIMITATIONS= | |LIMITATIONS= | ||
− | Mixed profiler types are not valid , Modal/Nodal | + | Mixed profiler types are not valid, Modal/Nodal |
Revision as of 15:41, 17 March 2014
Percentage of the movement length that will be not blended with the next movement.
- 0% – blending of second movement started from the beginning of the first one.
- 100% – blending of second movement started from the end of the first one (no blending).
Short form
BFPrev
Syntax
?<Axis>.BlendingFactorPrevious
<Axis>. BlendingFactorPrevious = <value>
Type
Double
Range
-1 to 100
Units
Percents of the segments length
Default
-1 (not active)
Scope
Task or Terminal
Limitations
Mixed profiler types are not valid, Modal/Nodal
Examples
Ax1.BlendingFactorPrevious= 10
?Ax1.BlendingFactorPrevious