Difference between revisions of "AXY:MC-Basic:group.DYNAMICMODEL"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<expression>''" to "<''expression''>")
m (Text replace - "R/W" to "Read/Write")
Line 38: Line 38:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
* R/W
+
* Read/Write
 
* Modal only
 
* Modal only
  

Revision as of 07:07, 19 March 2014

Dynamic model of a group.

The dynamic model calculates needed torques/forces for each joint of a robot during a commanded motion. The torques are then sent to the drives as "additional torque command" (torque feed forward), which helps to improve the motion performance.

Possible values:

0
No dynamic model. All dynamic computation during group motion for this group are disabled.
-1
Dynamic computations during group motions are based on the dynamic models of its axes.
In this case dynamic models must be enabled and parametrized for each axis separately.
During group/robot motions, the group payload (robot.PAYLOADINERTIA and robot.PAYLOADMASS) is used (instead of axes payloads). Other group dynamic parameters are ignored.
1 ..
See Axystems:Dynamic Models for a list of available robot models.
Model dependent parameters are expected to be set in Axystems:MC-Basic:robot.DYNAMICPARAMETER.

Syntax

<group>.DynamicModel = <expression>

Availability

AMCS 4.7.14

Type

Long

Range

-1, 0, 1 .. 15

Default

0 (No dynamic model)

Scope

Task and Terminal

Limitations

  • Read/Write
  • Modal only

See Also