Difference between revisions of "MC-Basic:axis.REALTIMECONTROLBIT"
m (Text replace - "''<axis>''" to "<''axis''>") |
m (Text replace - "''<value>''" to "<''value''>") |
||
Line 12: | Line 12: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | In SERCOS, a realtime control bit is set to activate a function. This property is used to set ('' | + | In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<''value''>) or query realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method. |
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | ||
Line 20: | Line 20: | ||
|RANGE= | |RANGE= | ||
− | '' | + | <''value''>: 0 or 1 |
''<bit_number>'':1 or 2 | ''<bit_number>'':1 or 2 |
Revision as of 09:02, 17 March 2014
In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<value>) or query realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<AXIS>.RTCB[ ]
Syntax
?<axis>.RTCB[<bit_number>]
<axis>.RTCB[<bit_numbrer>] = <value>
Availability
Available since version 4.5.18
Type
Long
Range
<value>: 0 or 1
<bit_number>:1 or 2
Scope
Configuration, Task or Terminal
Limitations
Can only be set during SERCOS communications phase 4.
Examples
?x_axis.rtcb[1]
x_axis.rtcb[2] = 1