Difference between revisions of "MC-Basic:axis.REALTIMECONTROLBIT"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<axis>''" to "<''axis''>")
m (Text replace - "''<value>''" to "<''value''>")
Line 12: Line 12:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
In SERCOS, a realtime control bit is set to activate a function. This property is used to set (''<value>'') or query realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
+
In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<''value''>) or query realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.
  
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
 
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}}
Line 20: Line 20:
  
 
|RANGE=
 
|RANGE=
''<value>'': 0 or 1
+
<''value''>: 0 or 1
  
 
''<bit_number>'':1 or 2
 
''<bit_number>'':1 or 2

Revision as of 09:02, 17 March 2014

In SERCOS, a realtime control bit is set to activate a function. This property is used to set (<value>) or query realtime control bit. The control bit is accessed using defined SERCOS IDNs, but this property provides a faster method.

IMPORTANT.svgIMPORTANT
THIS PROPERTY IS OBSOLETE

Short form

<AXIS>.RTCB[ ]

Syntax

?<axis>.RTCB[<bit_number>]

<axis>.RTCB[<bit_numbrer>] = <value>

Availability

Available since version 4.5.18

Type

Long

Range

<value>: 0 or 1

<bit_number>:1 or 2

Scope

Configuration, Task or Terminal

Limitations

Can only be set during SERCOS communications phase 4.

Examples

?x_axis.rtcb[1]

x_axis.rtcb[2] = 1