Difference between revisions of "MC-Basic:axis.FEEDBACK"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "''<axis>''" to "<''axis''>")
Line 4: Line 4:
  
 
|SYNTAX=
 
|SYNTAX=
<''axis''>.Feedback = ''<feedback source>''
+
<''axis''>.Feedback = <''feedback source''>
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Line 10: Line 10:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This property sets the source of the position feedback for the motion. The position feedback comes either from the motor (usually), or from the load. The load feedback is commonly used when working in the dual loop mode. Dual loop is set during the SERCOS phase run-up.
+
This property sets the source of the position feedback for the motion. The position feedback comes from either the motor (usually), or the load. The load feedback is commonly used when working in the dual loop mode. Dual loop is set during the SERCOS phase run-up.
  
 
When the feedback is set to external, the POSITIONFEEDBACK property is used to get feedback and calculate position following error. The POSITIONFEEDBACK units are defined by POSITIONFACTOR and not by POSITIONEXTERNALFACTOR.
 
When the feedback is set to external, the POSITIONFEEDBACK property is used to get feedback and calculate position following error. The POSITIONFEEDBACK units are defined by POSITIONFACTOR and not by POSITIONEXTERNALFACTOR.
Line 19: Line 19:
 
|RANGE=
 
|RANGE=
 
0 for Motor feedback<br>
 
0 for Motor feedback<br>
 
 
1 for External feedback
 
1 for External feedback
  

Revision as of 10:08, 18 March 2014

This property sets the source of the position feedback for the motion. The position feedback comes from either the motor (usually), or the load. The load feedback is commonly used when working in the dual loop mode. Dual loop is set during the SERCOS phase run-up.

When the feedback is set to external, the POSITIONFEEDBACK property is used to get feedback and calculate position following error. The POSITIONFEEDBACK units are defined by POSITIONFACTOR and not by POSITIONEXTERNALFACTOR.

Syntax

<axis>.Feedback = <feedback source>

Availability

All versions

Type

Long

Range

0 for Motor feedback
1 for External feedback

Default

0

Scope

Configuration, Task or Terminal

Examples

Axis1.Feedback = External

See Also