Difference between revisions of "MC-Basic:axis.DRIVEOPMODE"
m (Text replace - "''<axis>''" to "<''axis''>") |
|||
Line 12: | Line 12: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | This command allows you to change the operation mode of the controller. <''axis''>.DRIVEOPMODE may be changed from Primary Opmode to the Secondary Opmodes in CP4 when Primary Opmode ( IDN 32 ) and one or more Secondary Opmodes ( IDN 33 ,IDN 34 ) are defined in CP 2 ( | + | This command allows you to change the operation mode of the controller. <''axis''>.DRIVEOPMODE may be changed from Primary Opmode to the Secondary Opmodes in CP4 when Primary Opmode ( IDN 32 ) and one or more Secondary Opmodes (IDN 33, IDN 34) are defined in CP 2 (Refer to the ''SERCOS IDN Reference Manual''). |
For example : | For example : |
Revision as of 13:37, 17 March 2014
This command allows you to change the operation mode of the controller. <axis>.DRIVEOPMODE may be changed from Primary Opmode to the Secondary Opmodes in CP4 when Primary Opmode ( IDN 32 ) and one or more Secondary Opmodes (IDN 33, IDN 34) are defined in CP 2 (Refer to the SERCOS IDN Reference Manual).
For example :
'sercos.phase=2
'primary OpMode definition as position opmode
wival drive=A1.dadd IDN=32 value=3
'secondary OpMode1 definition as torque opmode
wival drive=A1.dadd IDN=33 value=1
'secondary OpMode2 definition
wival drive=A1.dadd IDN=34 value=2
Syntax
<axis>.DriveOpMode
? <axis>.DriveOpMode
Type
Long
Range
0 to 2
0 = Opmode ,defined as Primary ( IDN 32 )
1 = Opmode ,defined as Secondary Opmode1 ( IDN 33 )
2 = Opmode ,defined as Secondary Opmode2 ( IDN 34 )
Default
0
Scope
Configuration, Task, Terminal
Write Access Read/Write : R/W in CP4
Limitations
Primary Opmode and Secondary Opmodes must be defined in CP2. Executed only in SERCOS communication phase 4.
Examples
?Axes1.DriveOpMode
Axes1.DriveOpMode=2