Difference between revisions of "MC-Basic:axis.DRIVEON"
m (Text replace - "''<axis>''" to "<''axis''>") |
|||
Line 1: | Line 1: | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
− | '' | + | <''axis''>.DOn |
|SYNTAX= | |SYNTAX= | ||
− | '' | + | <''axis''>.DriveOn = ''<expression>''<br> |
− | ?'' | + | ?<''axis''>.DriveOn |
|AVAILABILITY= | |AVAILABILITY= | ||
Line 11: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
− | This property allows direct control over control bit 15. When this bit and bit 14 (DRIVEENABLE) are set to 1, the drive is enabled (if all other conditions for enable are met (e.g., no faults, remote enable is high)). This bit set to 0 results in an active disable on the drive (the drive stops the motor and then disable itself). Direct use of this bit is usually not necessary. Use the '' | + | This property allows direct control over control bit 15. When this bit and bit 14 (DRIVEENABLE) are set to 1, the drive is enabled (if all other conditions for enable are met (e.g., no faults, remote enable is high)). This bit set to 0 results in an active disable on the drive (the drive stops the motor and then disable itself). Direct use of this bit is usually not necessary. Use the <''axis''>.ENABLE property to enable and disable the drive. A query of this property returns the state of this request and not the state of the drive. |
{{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} | {{Note/Important| '''THIS PROPERTY IS OBSOLETE'''}} |
Revision as of 17:37, 16 March 2014
This property allows direct control over control bit 15. When this bit and bit 14 (DRIVEENABLE) are set to 1, the drive is enabled (if all other conditions for enable are met (e.g., no faults, remote enable is high)). This bit set to 0 results in an active disable on the drive (the drive stops the motor and then disable itself). Direct use of this bit is usually not necessary. Use the <axis>.ENABLE property to enable and disable the drive. A query of this property returns the state of this request and not the state of the drive.
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<axis>.DOn
Syntax
<axis>.DriveOn = <expression>
?<axis>.DriveOn
Availability
All versions
Type
Long
Range
0 or 1
Scope
Configuration, Task or Terminal
Limitations
Executed only in SERCOS communication phase 4.
Examples
?a1.don