Revision as of 17:39, 16 March 2014
This property determines the motor position feedback relative to the machine's zero point.
IMPORTANT | |
THIS PROPERTY IS OBSOLETE |
Short form
<axis>.Hoff
Syntax
<axis>.HomeOffset = <value>
Availability
All versions
Type
Double
Range
Limited by the drive.
Units
User position units
Default
Dependent on the drive
Scope
Terminal and Task
Limitations
Valid in communications phase 2 or higher.
To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
?a1.hoff
a1.hoff = -50