Difference between revisions of "MC-Basic:robot.VELOCITYDESYNCROT"

From SoftMC-Wiki
Jump to: navigation, search
(Created page with '{{MC-Basic |SHORT FORM= |SYNTAX= ''<ROBOT>.''VelocityDeSyncRot = <''numeric expression''> |AVAILABILITY= Version 0.4.0.22 and higher |DESCRIPTION= Not Used |TYPE= Double |R…')
 
m
 
(9 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:robot.VELOCITYDESYNCROT}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 7: Line 8:
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Version 0.4.0.22 and higher
+
Since Version 4.0.22
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Line 28: Line 29:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
R/W, Modal Only
+
Read/Write, Modal Only
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 34: Line 35:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:robot.VELOCITYDESYNCTRAN|robot.VELOCITYDESYNCTRAN]]
+
* [[MC-Basic:robot.VELOCITYDESYNCTRAN|robot.VELOCITYDESYNCTRAN]]
* [[Axystems:MC-Basic:ERROR! REFERENCE SOURCE NOT FOUND.|ERROR! REFERENCE SOURCE NOT FOUND.]]
+
* [[MC-Basic:robot.VELOCITYSYNCTRAN|robot.VELOCITYSYNCTRAN]]
* [[Axystems:MC-Basic:robot.VELOCITYSYNCTRAN|robot.VELOCITYSYNCTRAN]]
 
  
  
 
}}
 
}}
 +
[[Category:Motion:MovingFrame]]

Latest revision as of 01:53, 27 April 2017

Language: English  • 中文(简体)‎

Not Used

Syntax

<ROBOT>.VelocityDeSyncRot = <numeric expression>

Availability

Since Version 4.0.22

Type

Double

Range

0 to MaxDouble

Units

deg/sec

Default

4000

Scope

Configuration, Task or Terminal

Limitations

Read/Write, Modal Only

Examples

Scara.VelocityDeSyncRot = 500

See Also