Difference between revisions of "MC-Basic:robot.ACCELERATIONSYNCROT"

From SoftMC-Wiki
Jump to: navigation, search
m (1 revision)
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:robot.ACCELERATIONSYNCROT}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 7: Line 8:
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Version 0.4.0.22 and higher
+
Since Version 4.0.22
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Line 28: Line 29:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
R/W, Modal Only
+
Read/Write, Modal Only
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 34: Line 35:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:robot.ACCELERATIONDESYNCROT|robot.ACCELERATIONDESYNCROT]]
+
* [[MC-Basic:robot.ACCELERATIONDESYNCROT|robot.ACCELERATIONDESYNCROT]]
* [[Axystems:MC-Basic:robot.ACCELERATIONDESYNCTRAN|robot.ACCELERATIONDESYNCTRAN]]
+
* [[MC-Basic:robot.ACCELERATIONDESYNCTRAN|robot.ACCELERATIONDESYNCTRAN]]
* [[Axystems:MC-Basic:robot.ACCELERATIONSYNCTRAN|robot.ACCELERATIONSYNCTRAN]]
+
* [[MC-Basic:robot.ACCELERATIONSYNCTRAN|robot.ACCELERATIONSYNCTRAN]]
  
  
 
}}
 
}}
 +
[[Category:Motion:MovingFrame]]

Latest revision as of 01:36, 28 April 2017

Language: English  • 中文(简体)‎

Accleration value of the rotational moving frame componenet Used during synchronization process for target prediction (from the time tracking is started (e.g. Slave=5) until it is synchronized with moving frame <robot>.IMFS = 1)

Syntax

<ROBOT>.AccelerationSyncRot = <numeric expression>

Availability

Since Version 4.0.22

Type

Double

Range

0 to MaxDouble

Units

deg/sec²

Default

400000

Scope

Configuration, Task or Terminal

Limitations

Read/Write, Modal Only

Examples

Scara.AccelerationSyncRot  = 500