Stop the Phaser command . It stops the convergence stage of the Phaser command. Ratio is used to correlate between master and slave unit and to control the stop rate.
Syntax
StopPhase <slave axis> ratio = <ratio factor>
Availability
Versions 4.0.x and higher
Range
<offset> : mindouble to maxdouble
<ratio factor> : above then zero
Units
<offset> : master position units
<ratio factor> : [master position unites / slave position units]
Default
<ratio factor> : 1
Scope
Task, terminal
Limitations
Axis must be slaved, command can’t be executed without offset value. Valid for axis only.
Examples
A1.mastersource = a2.pcmd
A1.slave = CAM
Phase a1 10 ratio = 1