Difference between revisions of "MC-Basic:RECORDING"

From SoftMC-Wiki
Jump to: navigation, search
(Created page with '{{MC-Basic |SHORT FORM= |SYNTAX= ?Recording |AVAILABILITY= All versions |DESCRIPTION= This query returns the state of the data recorder. The following values are returned:<br…')
 
m
 
(9 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:RECORDING}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 37: Line 38:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
Read-Only
+
Read only
  
 
|EXAMPLE=
 
|EXAMPLE=
Line 43: Line 44:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:RECORD|RECORD]]
+
* [[MC-Basic:RECORD|RECORD]]
* [[Axystems:MC-Basic:RECORDCLOSE|RECORDCLOSE]]
+
* [[MC-Basic:RECORDCLOSE|RECORDCLOSE]]
* [[Axystems:MC-Basic:RECORDOFF|RECORDOFF]]
+
* [[MC-Basic:RECORDOFF|RECORDOFF]]
* [[Axystems:MC-Basic:RECORDON|RECORDON]]
+
* [[MC-Basic:RECORDON|RECORDON]]
 
 
  
 +
[[Category:MC-Basic:Data Recording|RECORDING]]
 
}}
 
}}

Latest revision as of 08:07, 27 April 2017

Language: English  • 中文(简体)‎

This query returns the state of the data recorder. The following values are returned:
       0 - recorder undefined and inactive.

1 - Recorder is defined, but inactive. (The RECORDON command is needed to activate it.)

2 - Recording is in progress (Data acquisition process after RECORDON was given.)

3 - Recording suspended. (RECORDOFF command issued.)

4 - Data acquisition completed automatically. Recorder is still defined. (RECORDCLOSE command needed to flush the data to the disk.)

Syntax

?Recording

Availability

All versions

Type

Long

Range

0 to 4

Scope

Task or Terminal

Limitations

Read only

Examples

?Recording