Difference between revisions of "MC-Basic:axis.BUSNUMBER"

From SoftMC-Wiki
Jump to: navigation, search
m
(the default busnumber value is updated to 4)
 
(One intermediate revision by one other user not shown)
Line 1: Line 1:
{{Languages}}
+
{{Languages|MC-Basic:axis.BUSNUMBER}}  
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 16: Line 16:
  
 
|RANGE=
 
|RANGE=
-1 - Default value, after start up or "reset all"<br>
+
(4) - Default value, after start up or "reset all"<br>
 
0 - EtherCAT<br>
 
0 - EtherCAT<br>
 
1 - CANopen
 
1 - CANopen

Latest revision as of 14:06, 1 April 2020

Language: English  • 中文(简体)‎

This property sets the field bus to which the axis is connected

Syntax

?<axis>.BusNumber

Availability

Since Version 4.15.2
0 - EtherCAT
1 - CANopen

Type

Long

Range

(4) - Default value, after start up or "reset all"
0 - EtherCAT
1 - CANopen

Scope

Configuration, Task or Terminal.

Limitations

Till version 4.15.2 Read-only

Examples

?Axis1.BusNumber