Difference between revisions of "MC-Basic:axis.UserFollowingMode"

From SoftMC-Wiki
Jump to: navigation, search
 
Line 1: Line 1:
{{Languages}}
+
{{Languages|MC-Basic:axis.UserFollowingMode}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 25: Line 25:
 
<!-- -2 – User following by (PCMD = PCMD<sub>0</sub>). Relevant only when drive status <b>BIT3</b> is set. Exit this type of following mode by setting PCMD using SDO_0x208e  AT cyclic telegram.<br> -->
 
<!-- -2 – User following by (PCMD = PCMD<sub>0</sub>). Relevant only when drive status <b>BIT3</b> is set. Exit this type of following mode by setting PCMD using SDO_0x208e  AT cyclic telegram.<br> -->
 
-3 – User following by (PCMD = PCMD<sub>0</sub>). Freezing the PCMD value so it's won't be changed with drive's PFB exit, Relevant only when drive status <b>BIT3</b> is set.  Exit this type of following mode by setting PCMD using drive PFB AT cyclic telegram.<br>
 
-3 – User following by (PCMD = PCMD<sub>0</sub>). Freezing the PCMD value so it's won't be changed with drive's PFB exit, Relevant only when drive status <b>BIT3</b> is set.  Exit this type of following mode by setting PCMD using drive PFB AT cyclic telegram.<br>
 +
 +
 +
 +
{{Note|For '''BIT3''' see: [[MC-Basic:axis.DRIVESTATUS|axis.DRIVESTATUS]]}}
  
 
|UNITS=
 
|UNITS=

Latest revision as of 11:02, 28 February 2018

Language: English  • 中文(简体)‎

The type of the Following mode can be defined by setting different values into FOLLOWINGMODE. The query on this property returns the internal state (See Range)
The current property comes to help the user to query what is the following-mode type.

Short form

<axis>.UserFmode

Syntax

?<axis>.UserFollowingMode

Availability

Since Version 4.10.x

Type

Long

Range

0 – (Default) No user following mode
1 - User - Following: freeze PCMD value so it's won't be changed.
2 – Soft user following mode, keeps PositionCommand equal to PositionFeedback
-3 – User following by (PCMD = PCMD0). Freezing the PCMD value so it's won't be changed with drive's PFB exit, Relevant only when drive status BIT3 is set. Exit this type of following mode by setting PCMD using drive PFB AT cyclic telegram.


NOTE-Info.svgNOTE
For BIT3 see: axis.DRIVESTATUS

Units

Integer

Default

0

Scope

Configuration, Task or Terminal

Limitations

  • Read only
  • Valid for axis only

Examples

?X_Axis.FollowingMode

See Also