Difference between revisions of "MC-Basic:axis.FASTDATAENABLE"
(AXY: new links) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | {{Languages}} | + | {{Languages|MC-Basic:axis.FASTDATAENABLE}} |
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 50: | Line 50: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * | + | * [MC-Basic:element.ISMOVING|ISMOVING]] |
− | * [[MC-Basic: | + | * [[MC-Basic:element.ISSETTLED|ISSETTLED]] |
}} | }} |
Latest revision as of 11:07, 13 September 2017
Language: | English • 中文(简体) |
---|
This property enables or disables fast data information transfer. When axis fast data are enabled, axis status and feedback information is transferred to the host every SERCOS cycle.
Axis status and feedback information are available for the first 8 axes in the system. In a given system, only the data for the defined number of axes are available.
Two bytes are allocated for axis status information. The following status bits are returned. All unused bits return 0.
ISSETTLED: set to 1 when the axis is settled
ISMOVING: Set to 1 while the profiler is active
DRIVEENABLED: set to 1 while the axis is enabled
DRIVEFAULT: Set to 1 when a fault exists on the drive
Axis position and velocity feedback are returned. Each item is returned as a double precision floating point number (8 bytes) in user units.
Short form
<axis>.FDEn
Syntax
<axis>.FastDataEnable = <value>
?<axis>.FastDataEnable
Availability
All versions
Type
Long
Range
0 (OFF)
1 (ON)
Default
OFF
Scope
Configuration, Task or Terminal
Limitations
Supported only in SERCOS systems Enabling the fast data increases the realtime load by a small amount.
Examples
xaxis.Fden = ON
See Also
- [MC-Basic:element.ISMOVING