Difference between revisions of "MC-Basic:axis.DECELERATIONSTOP"
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{Languages}} | + | {{Languages|MC-Basic:axis.DECELERATIONSTOP}} |
− | + | {{MC-Basic | |
− | <''axis''>.DecStop | + | |SHORT FORM= |
+ | ''<''axis''>''.DecStop | ||
− | + | |SYNTAX= | |
− | <''axis''>.DecelerationStop = <''value''> | + | ''<''axis''>.''DecelerationStop = <''value''> |
− | + | |AVAILABILITY= | |
− | |||
− | |||
− | == | + | |DESCRIPTION= |
+ | DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases? -single axis movement,? or group movement from type Move or Circle. | ||
+ | |||
+ | |TYPE= | ||
Double | Double | ||
Read/Write | Read/Write | ||
− | + | |RANGE= | |
0.01 to Max Double | 0.01 to Max Double | ||
− | + | |UNITS= | |
Acceleration user units | Acceleration user units | ||
− | + | |DEFAULT= | |
1000 | 1000 | ||
− | + | |SCOPE= | |
Terminal or task | Terminal or task | ||
− | + | |LIMITATIONS= | |
Modal Only. | Modal Only. | ||
− | + | |EXAMPLE= | |
A1.DecStop = 1000 | A1.DecStop = 1000 | ||
− | + | |SEE ALSO= | |
− | * [[MC-Basic: | + | * [[MC-Basic:element.ACCELERATION|axis.ACCELERATION]] |
− | * [[MC-Basic:axis.ACCELERATIONMAX|axis.ACCELERATIONMAX]] | + | * [[Category talk:MC-Basic:axis.ACCELERATIONMAX|axis.ACCELERATIONMAX]] |
− | * [[MC-Basic: | + | * [[MC-Basic:element.DECELERATION|axis.DECELERATION]] |
− | * [[MC-Basic: | + | * [[MC-Basic:element.DECELERATIONMAX|axis.DECELERATIONMAX]] |
+ | }} |
Latest revision as of 08:45, 16 July 2018
Language: | English • 中文(简体) |
---|
DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases? -single axis movement,? or group movement from type Move or Circle.
Short form
<axis>.DecStop
Syntax
<axis>.DecelerationStop = <value>
Type
Double
Read/Write
Range
0.01 to Max Double
Units
Acceleration user units
Default
1000
Scope
Terminal or task
Limitations
Modal Only.
Examples
A1.DecStop = 1000