Difference between revisions of "MC-Basic:axis.BUSNUMBER"
(Updated limitations and availability) |
(the default busnumber value is updated to 4) |
||
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.BUSNUMBER}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 10: | Line 11: | ||
|DESCRIPTION= | |DESCRIPTION= | ||
+ | This property sets the field bus to which the axis is connected | ||
|TYPE= | |TYPE= | ||
Long | Long | ||
|RANGE= | |RANGE= | ||
+ | (4) - Default value, after start up or "reset all"<br> | ||
0 - EtherCAT<br> | 0 - EtherCAT<br> | ||
1 - CANopen | 1 - CANopen |
Latest revision as of 14:06, 1 April 2020
Language: | English • 中文(简体) |
---|
This property sets the field bus to which the axis is connected
Syntax
?<axis>.BusNumber
Availability
Since Version 4.15.2
0 - EtherCAT
1 - CANopen
Type
Long
Range
(4) - Default value, after start up or "reset all"
0 - EtherCAT
1 - CANopen
Scope
Configuration, Task or Terminal.
Limitations
Till version 4.15.2 Read-only
Examples
?Axis1.BusNumber