Difference between revisions of "MC-Basic:axis.POSITIONEXTERNALFACTOR"
(AXY: new links) |
|||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.POSITIONEXTERNALFACTOR}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 38: | Line 39: | ||
* [[MC-Basic:axis.VELOCITYEXTERNALFACTOR|axis.VELOCITYEXTERNALFACTOR]] | * [[MC-Basic:axis.VELOCITYEXTERNALFACTOR|axis.VELOCITYEXTERNALFACTOR]] | ||
* [[MC-Basic:axis.POSITIONEXTERNALFACTOR|axis.POSITIONEXTERNALFACTOR]] | * [[MC-Basic:axis.POSITIONEXTERNALFACTOR|axis.POSITIONEXTERNALFACTOR]] | ||
− | * [[MC-Basic: | + | * [[MC-Basic:element.POSITIONFEEDBACK|POSITIONFEEDBACK]] |
* [[MC-Basic:axis.VELOCITYEXTERNAL|axis.VELOCITYEXTERNAL]] | * [[MC-Basic:axis.VELOCITYEXTERNAL|axis.VELOCITYEXTERNAL]] | ||
* [[MC-Basic:axis.VELOCITYEXTERNALFACTOR|axis.VELOCITYEXTERNALFACTOR]] | * [[MC-Basic:axis.VELOCITYEXTERNALFACTOR|axis.VELOCITYEXTERNALFACTOR]] |
Latest revision as of 12:01, 13 September 2017
Language: | English • 中文(简体) |
---|
The position factor of the external feedback is used to convert that value from counts into physical units.
Short form
<axis>.PExtfac
Syntax
<axis>.PositionExternalFactor = <expression>
?<axis>.PositionExternalFactor
Availability
All versions
Type
Double
Range
Greater than 0
Default
1
Scope
Configuration, Task or Terminal
Limitations
- Drive must be disabled.
- To set the value within a task, the axis must be attached to that task (using the ATTACH command).
Examples
A1.PositionExternalFactor = 2048