Difference between revisions of "MC-Basic:REDIRECTSTDOUT"

From SoftMC-Wiki
Jump to: navigation, search
(Upadate entry station number)
 
(4 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:REDIRECTSTDOUT}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 4: Line 5:
  
 
|SYNTAX=
 
|SYNTAX=
RedirectStdOut'' <task name>'' NewStdOut=<''es number''>
+
RedirectStdOut{'' <task name>''} NewStdOut=<''es number''>
  
 
|AVAILABILITY=
 
|AVAILABILITY=
Line 10: Line 11:
  
 
|DESCRIPTION=
 
|DESCRIPTION=
Redirects the printouts from the parent entry station of a task to the specified entry station. The ES number can be:<br>
+
Redirects the printouts from the parent entry station of a task to the specified entry station. <br>
       1 & 4 (Alternating) – Ethernet on port 5001<br>
+
The ES number can be found at:<br>
       2 – Ethernet on port 5003<br>
+
* [[MC-Basic:ENTRYSTATIONTYPE|ENTRYSTATIONTYPE]]
       3 – Virtual Entry Station<br>
 
       5 – Etherent on port 5004<br>
 
  
 +
if optional <task name> is left empty, redirect applies to the current task.<br>
  
 
|TYPE=
 
|TYPE=

Latest revision as of 13:43, 22 August 2019

Language: English  • 中文(简体)‎

Redirects the printouts from the parent entry station of a task to the specified entry station.
The ES number can be found at:

if optional <task name> is left empty, redirect applies to the current task.

Syntax

RedirectStdOut{ <task name>} NewStdOut=<es number>

Availability

Since Version 3.7.x

Type

<es number> : Long

Scope

Configuration, Task, Terminal

Examples

RedirectStdOut  Job1.prg  NewStdOut=1

See Also