Difference between revisions of "SERCOS Operation Modes"
m (→SERCOS IDN's) |
m (→Structure of Drive Operation Modes) |
||
(4 intermediate revisions by the same user not shown) | |||
Line 30: | Line 30: | ||
|} | |} | ||
− | == | + | == Structure of Drive Operation Modes== |
− | {| border=" | + | {| border="1px" cellpadding="3" cellspacing="0" |
|1= manufacturer operation mode | |1= manufacturer operation mode | ||
0= SERCOS operation mode | 0= SERCOS operation mode | ||
Line 90: | Line 90: | ||
|} | |} | ||
− | ==See Also | + | ==See Also == |
− | |||
[[Category:OperationalModes]] | [[Category:OperationalModes]] |
Latest revision as of 08:22, 28 May 2014
Contents
SERCOS Operation Modes
SERCOS IDNs
IDN | Description |
S-0-0032 | Primary operation mode |
S-0-0033 | Secondary operation mode 1 |
S-0-0034 | Secondary operation mode 2 |
S-0-0035 | Secondary operation mode 3 |
S-0-0284 | Secondary operation mode 4 |
S-0-0285 | Secondary operation mode 5 |
S-0-0286 | Secondary operation mode 6 |
S-0-0287 | Secondary operation mode 7 |
S-0-0292 | List of supported operation modes |
S-0-0520 | Axis control word |
S-0-0521 | Axis status word |
Structure of Drive Operation Modes
1= manufacturer operation mode
0= SERCOS operation mode |
reserved | 0= without axis control word
1= with axis control word (S-0-0520) |
0= without transition support
1= with transition support |
Expanded operation modes | 0= with following error
1= without following error |
Basic operation modes | Operation modes |
15 | 14 - 10 | 9 | 8 | 7 - 4 | 3 | 2 1 0 | Bit number |
1 | xx xxx | x | x | xxxx | x | xxx | Operation mode (bits 14-0) defined by manufacturer |
0 | 000 00 | 0 | 0 | 0000 | x | 000 | No operation mode defined |
0 | 000 00 | 0 | 0 | 0000 | x | 001 | Torque/Force control |
0 | 000 00 | 0 | 0 | 0000 | x | 010 | Velocity control |
0 | 000 00 | 0 | 0/1 | 0000 | 0/1 | 011 | Position control using position feedback value 1 |
0 | 000 00 | 0 | 0/1 | 0000 | 0/1 | 100 | Position control using position feedback value 2 |
0 | 000 00 | 0 | 0/1 | 0000 | 0/1 | 101 | Position control using position feedback values 1 and 2 |
0 | 000 00 | 1 | 0 | 0000 | x | 101 | Position control using axis control word |
0 | 000 00 | 0 | 0 | 0000 | 0 | 110 | Pressure control |
0 | 000 00 | 0 | 0 | 0000 | x | 111 | Operation mode without control loops |
0 | 000 00 | 0 | 0/1 | 0001 | 0/1 | 011 | Interpolation using position feedback value 1 |
0 | 000 00 | 0 | 0/1 | 0001 | 0/1 | 100 | Interpolation using position feedback value 2 |
0 | 000 00 | 0 | 0/1 | 0001 | 0/1 | 101 | Interpolation using position feedback values 1 and 2 |
0 | 000 00 | 1 | 0 | 0001 | x | 101 | Interpolation using axis control word |
0 | 000 00 | 0 | 0/1 | 0010 | 0/1 | 011 | Positioning using position feedback value 1 |
0 | 000 00 | 0 | 0/1 | 0010 | 0/1 | 100 | Positioning using position feedback value 2 |
0 | 000 00 | 0 | 0/1 | 0010 | 0/1 | 101 | Positioning using position feedback values 1 and 2 |
0 | 000 00 | 1 | 0 | 0010 | x | 101 | Positioning using axis control word |
0 | 000 00 | 0 | 0/1 | 0011 | 0/1 | 011 | Block mode using position feedback value 1 |
0 | 000 00 | 0 | 0/1 | 0011 | 0/1 | 100 | Block mode using position feedback value 2 |