Difference between revisions of "MC-Basic:axis.CountRollOver"
(4 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.CountRollOver}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 4: | Line 5: | ||
?<''axis''>.CountRollover | ?<''axis''>.CountRollover | ||
|AVAILABILITY=From ver 4.7.13 | |AVAILABILITY=From ver 4.7.13 | ||
− | |DESCRIPTION= | + | |DESCRIPTION=There are drives as BOSCH drives where there are two standard IDN defining minimum and maximum |
+ | values of counts rollover.<br/> | ||
This property indicates the number of rollovers that were passed in the drive. Setting to zero resets the counter. | This property indicates the number of rollovers that were passed in the drive. Setting to zero resets the counter. | ||
|TYPE= integer | |TYPE= integer | ||
Line 21: | Line 23: | ||
* [[MC-Basic:axis.CountExtMin|axis.CountExtMin]] | * [[MC-Basic:axis.CountExtMin|axis.CountExtMin]] | ||
* [[MC-Basic:axis.CountExtRollOver|axis.CountExtRollOver]] | * [[MC-Basic:axis.CountExtRollOver|axis.CountExtRollOver]] | ||
− | * [[ | + | * [[Endless Axes| Infinite Axes]] |
<!-- {{Bugzilla|5339}} --> | <!-- {{Bugzilla|5339}} --> | ||
}} | }} |
Latest revision as of 06:18, 18 April 2017
Language: | English • 中文(简体) |
---|
There are drives as BOSCH drives where there are two standard IDN defining minimum and maximum
values of counts rollover.
This property indicates the number of rollovers that were passed in the drive. Setting to zero resets the counter.
Syntax
?<axis>.CountRollover
Availability
From ver 4.7.13
Type
integer
Range
min-max integer
Units
int
Default
none
Scope
Configuration, Task or Terminal
Limitations
- Axis only
- Can be set only when the drive is disabled