Difference between revisions of "MC-Basic:SYSTEM.DIPSWITCH"

From SoftMC-Wiki
Jump to: navigation, search
m (Miborich moved page Axystems:MC-Basic:SYSTEM.DIPSWITCH to MC-Basic:SYSTEM.DIPSWITCH: Global renaming of Axystems: namespace into (Main):)
 
(2 intermediate revisions by one other user not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:SYSTEM.DIPSWITCH}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 66: Line 67:
  
  
 +
[[Category:MC-Basic:System|MC-Basic:System]]
 
}}
 
}}

Latest revision as of 02:07, 2 May 2017

Language: English  • 中文(简体)‎

SYSTEM.DIPSWITCH reads a value of simulated DIP-Switch from file IO.DAT, from field "DIP". It contains the values of the individual bits in the DIPswitch byte. If SYSTEM.DIPSWITCH is qualified by a bit number, only that input bit is read. SYSTEM.DIPSWITCH.<bit_number> returns the value 1 or 0, depending on the setting of the switch.


File IO.DAT is generated automatically if it does not exist on the flash disk.
Format of IO.DAT
DIP=0xXX
INP=0xXX

Value of simulated DIP-Switch is read via SYSTEM.DIN Value of simulated Inputs is read via SYSTEM.DIN.1 trough SYSTEM.DIN.23

Bit # 6 directs the system not to load the Config.prg file during system startup.
       0= Config.prg and Autoexec.prg are not loaded.
       1 = Config.prg and Autoexec.prg are loaded. Default value should be 1 during normal operation.

Other bits reserved for system use.

Syntax

System.DipSwitch{.<bit number>}

Sys.DipSwitch{.<bit number>}

?System.DipSwitch{.<bit number>}

?Sys.DipSwitch{.<bit number>}

Availability

Since version 4.11.1

Type

<bit number>: Long

Value: Long

Range

<bit number>: 1 to 8

Value: 0 to 255 (0xFF)

Default

See description.

Scope

Configuration, Task or Terminal

Limitations

Read only

Examples

MyVar = System.DipSwitch

'MyVar is assigned the value of the input word

MyVar = System.DipSwitch.1

'MyVar is assigned 0 or 1, according to the value of the switch