Difference between revisions of "EtherCAT:EC SET IO MODULE OUTPUT"

From SoftMC-Wiki
Jump to: navigation, search
m (Miborich moved page Axystems:EtherCAT:EC SET IO MODULE OUTPUT to EtherCAT:EC SET IO MODULE OUTPUT: Global renaming of Axystems: namespace into (Main):)
 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Axystems:Template:EtherCAT-Function
+
{{Languages|EtherCAT:EC_SET_IO_MODULE_OUTPUT}}
 +
{{Template:EtherCAT-Function
  
 
|DESCRIPTION=
 
|DESCRIPTION=
This subroutine sets an IO module's outputON (1) or OFF (0).
+
This subroutine sets an IO module output to ON (1) or OFF (0).<br/>
 +
It is easier to set digital I/Os if they are associated with system's digital I/Os.<br/>
 +
Refer to [[EtherCAT:DIGITAL-IOS|Digital I/Os]] for more information.<br/>
  
 
|INPUT=
 
|INPUT=

Latest revision as of 17:46, 6 May 2017

Language: English  • 中文(简体)‎

This subroutine sets an IO module output to ON (1) or OFF (0).
It is easier to set digital I/Os if they are associated with system's digital I/Os.
Refer to Digital I/Os for more information.

Input

Slave address, PDO index, PDO sub-index, new LED setting.

Output

None

Return Value

Void

Declaration

public sub EC_SET_IO_MODULE_OUTPUT(byval slaveaddress as long, byval index as long, byval subindex as long, byval new_val as long)

Syntax

call EC_SET_IO_MODULE_OUTPUT(<Slave address>, <PDO index>, <PDO sub-index>, <LED setting>)

Examples

call EC_SET_IO_MODULE_OUTPUT(1, 0x7020, 0x01, 1) call EC_SET_IO_MODULE_OUTPUT(1, 0x7040, 0x01, 0)