Difference between revisions of "MC-Basic:IdentificationStart"
(11 intermediate revisions by 2 users not shown) | |||
Line 10: | Line 10: | ||
{IdentRecTimeMax = <''value''>} | {IdentRecTimeMax = <''value''>} | ||
{IdentDebug = ''ON<nowiki>|</nowiki>OFF''} | {IdentDebug = ''ON<nowiki>|</nowiki>OFF''} | ||
+ | {IdentSampleGap = <''value''>} | ||
|AVAILABILITY= | |AVAILABILITY= | ||
Line 19: | Line 20: | ||
The typical identification procedure basically contains following steps: | The typical identification procedure basically contains following steps: | ||
# With ''IdentificationStart'' the identification is configured and the internal recording of the feedback signals is started. | # With ''IdentificationStart'' the identification is configured and the internal recording of the feedback signals is started. | ||
− | # A kinematics-specific excitation motion is issued by the user (typically [[ | + | # A kinematics-specific excitation motion is issued by the user (typically [[MC-Basic:SineWave|SineWave]] is used). |
− | # With ''[[ | + | # With ''[[MC-Basic:IdentificationFinish|IdentificationFinish]]'' the parameters are computed and written to the result file ''IdentFileName''.prg. |
=== Parameters === | === Parameters === | ||
Line 52: | Line 53: | ||
:* Filtered and derived (velocity, acceleration) feedbacks (Tfb, Pfb, Vfb, Afb) | :* Filtered and derived (velocity, acceleration) feedbacks (Tfb, Pfb, Vfb, Afb) | ||
:* Torque command, which is computed using the identified parameters (Tcmd) | :* Torque command, which is computed using the identified parameters (Tcmd) | ||
+ | |||
+ | ;IdentSampleGap | ||
+ | : The recording gap between data points in cycle time units. | ||
|TYPE= | |TYPE= | ||
Line 59: | Line 63: | ||
* ''IdentRelTeMax'' : Double | * ''IdentRelTeMax'' : Double | ||
* ''IdentRecTimeMax '' : Double | * ''IdentRecTimeMax '' : Double | ||
+ | * ''IdentSampleGap'' : Long | ||
Line 68: | Line 73: | ||
* ''IdentRelTeMax'' : Percent [%] | * ''IdentRelTeMax'' : Percent [%] | ||
* ''IdentRecTimeMax'' : Seconds [s] | * ''IdentRecTimeMax'' : Seconds [s] | ||
+ | * ''IdentSampleGap'' : Cycle Time | ||
|DEFAULT= | |DEFAULT= | ||
Line 77: | Line 83: | ||
* ''IdentRecTimeMax'' : 30s | * ''IdentRecTimeMax'' : 30s | ||
* ''IdentDebug'' : ON | * ''IdentDebug'' : ON | ||
+ | * ''IdentSampleGap'' : 1 | ||
|SCOPE= | |SCOPE= | ||
Line 101: | Line 108: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[Motion Dynamics]] |
− | * [[ | + | * [[MC-Basic:IdentificationFinish|IdentificationFinish]] |
− | * [[ | + | * [[MC-Basic:IdentificationStatus|IdentificationStatus]] |
− | * [[ | + | * [[MC-Basic:IdentificationCancel|IdentificationCancel]] |
− | * [[ | + | * [[MC-Basic:SineWave|SineWave]] |
− | + | * [[Dynamic Models|Dynamic Models]] | |
}} | }} | ||
− | [[Category | + | [[Category:Motion Dynamics]] |
Latest revision as of 11:48, 16 October 2018
Starts dynamic parameters identification for an axis or a robot.
The typical identification procedure basically contains following steps:
- With IdentificationStart the identification is configured and the internal recording of the feedback signals is started.
- A kinematics-specific excitation motion is issued by the user (typically SineWave is used).
- With IdentificationFinish the parameters are computed and written to the result file IdentFileName.prg.
Parameters
- IdentDynamicModel
- The dynamic model of which the parameters are identified.
- If not given, the current dynamic model of the motion element is used.
- The values 0 or -1 not allowed:
- If Payload is ON, DynamicModel value is ignored.
- IdentPayload
- If ON, the payload (payloadmass, payloadinertia) is identified instead of the model parameters.
- IdentFilterFreq
- Cutoff frequency of the raw signal filter.
- 0 = the frequency is automatically detected
- -1 = no filter is used at all
- IdentFileName
- File name without extension of the output files (.PRG, .REC)
- If not given, files are called "IDNT<ElementId>"
- IdentRelTeMax
- Percentage of the maximal torque error compared to the maximal torque feedback of an axis. If the maximal TE is higher, the identification is considered to be failed.
- IdentRecTimeMax
- Maximal recording time after the start of identification.
- IdentDebug
- If enabled, a record file is produced on the softMC containing the signals used for identification:
- Raw torque and position feedbacks (TbfRaw and PfbRaw)
- Filtered and derived (velocity, acceleration) feedbacks (Tfb, Pfb, Vfb, Afb)
- Torque command, which is computed using the identified parameters (Tcmd)
- IdentSampleGap
- The recording gap between data points in cycle time units.
Syntax
IdentificationStart <axis>|<robot> {IdentDynamicModel = <value>} {IdentPayload = ON|OFF} {IdentFilterFreq = <value>} {IdentFileName = <value>} {IdentRelTeMax = <value>} {IdentRecTimeMax = <value>} {IdentDebug = ON|OFF} {IdentSampleGap = <value>}
Availability
Since Version 4.9.7
Type
- IdentDynamicModel : Long
- IdentFilterFreq : Double
- IdentFileName : String
- IdentRelTeMax : Double
- IdentRecTimeMax : Double
- IdentSampleGap : Long
Range
- IdentDynamicModel : 1, 2, 3, .. (only positive numbers, see available models)
Units
- IdentFilterFreq : Herz [Hz]
- IdentRelTeMax : Percent [%]
- IdentRecTimeMax : Seconds [s]
- IdentSampleGap : Cycle Time
Default
- IdentDynamicModel : element.DynamicModel
- IdentPayload : OFF
- IdentFilterFreq : 0 (auto-detect)
- IdentFileName : "" (auto-assign)
- IdentRelTeMax : 50%
- IdentRecTimeMax : 30s
- IdentDebug : ON
- IdentSampleGap : 1
Scope
Task or Terminal
Limitations
- Only one motion element can be identified at the same time.
Examples
Move axis axis.Pmax SineWave axis axis.Pmin IdentificationStart axis Sleep 10000 IdentificationFinish Print IdentificationStatus Stop axis