Difference between revisions of "MC-Basic:axis.PIPEMODE"
m |
|||
(3 intermediate revisions by one other user not shown) | |||
Line 1: | Line 1: | ||
+ | {{Languages|MC-Basic:axis.PIPEMODE}} | ||
{{MC-Basic | {{MC-Basic | ||
|SHORT FORM= | |SHORT FORM= | ||
Line 42: | Line 43: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:SYSTEM.PIPEMODE|SYSTEM.PIPEMODE]] |
− | [[Category | + | [[Category:Obsolete|axis.PIPEMODE]] |
}} | }} |
Latest revision as of 03:20, 20 April 2017
Language: | English • 中文(简体) |
---|
This property enables the axis Pipe mode operation. When axis Pipe mode is active, the position and velocity commands to the drive are taken from the Sys.HostDouble[] variables. To engage, sys.pmode must be set to ON.
Short form
<axis>.PMode
Syntax
<axis>.PMode = <expression>
?<axis>.PMode
Availability
Versions 4.0.2 and higher
Type
Long
Range
0 (OFF)
1 (ON)
Default
OFF
Scope
Config, Task or Terminal
Limitations
- When Sys.PipeMode = 1, axes A1…A8 can operate in Pipe mode
- When Sys.PipeMode = 2, axes A1…A4 can operate in Pipe mode
- Not supported in EtherCAT system
Examples
<axis>.PMode = ON
?<axis>.PMode