Difference between revisions of "MC-Basic:BUS.BAUDRATE"

From SoftMC-Wiki
Jump to: navigation, search
m (Text replace - "|AVAILABILITY= Version 4.9.11" to "|AVAILABILITY= Since Version 4.9.11")
(Added example)
 
(4 intermediate revisions by 4 users not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:BUS.BAUDRATE}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 23: Line 24:
  
 
|DEFAULT=
 
|DEFAULT=
 
+
CAN 1 mbps
  
 
|SCOPE=
 
|SCOPE=
Line 29: Line 30:
  
 
|LIMITATIONS=
 
|LIMITATIONS=
*Supported in SERCOS II
+
*Supported in:<br>
 +
SERCOS II<br>
 +
CANopen
 +
 
 
|EXAMPLE=
 
|EXAMPLE=
 
?BUS[0].Baudrate<br>
 
?BUS[0].Baudrate<br>
BUS[0].Baudrate =  
+
BUS[0].Baudrate = 1000000 ' set 1 mbps bit rate
  
 
|SEE ALSO=
 
|SEE ALSO=

Latest revision as of 07:09, 4 March 2018

Language: English  • 中文(简体)‎

Syntax

?BUS[<bus_number>].Baudrate
BUS[<bus_number>].Baudrate = <expression>

Availability

Since Version 4.9.11

Type

<return value>: Long
<bus_number>: Long
<expression>: Long, Double

Default

CAN 1 mbps

Scope

Configuration, Task or Terminal

Limitations

  • Supported in:

SERCOS II
CANopen

Examples

?BUS[0].Baudrate
BUS[0].Baudrate = 1000000 ' set 1 mbps bit rate