Difference between revisions of "MC-Basic:WRITEIDNVALUEARRAY"

From SoftMC-Wiki
Jump to: navigation, search
m
 
(5 intermediate revisions by one other user not shown)
Line 1: Line 1:
 +
{{Languages|MC-Basic:WRITEIDNVALUEARRAY}}
 
{{MC-Basic
 
{{MC-Basic
 
|SHORT FORM=
 
|SHORT FORM=
Line 62: Line 63:
  
 
|SEE ALSO=
 
|SEE ALSO=
* [[Axystems:MC-Basic:IDNSTRING|IDNSTRING]]
+
* [[MC-Basic:IDNSTRING|IDNSTRING]]
* [[Axystems:MC-Basic:IDNVALUE|IDNVALUE]]
+
* [[MC-Basic:IDNVALUE|IDNVALUE]]
* [[Axystems:MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
+
* [[MC-Basic:WRITEIDNSTRING|WRITEIDNSTRING]]
  
[[Category:Axystems:Obsolete|WRITEIDNVALUEARRAY]]
+
[[Category:Obsolete|WRITEIDNVALUEARRAY]]
 
}}
 
}}

Latest revision as of 17:04, 2 May 2017

Language: English  • 中文(简体)‎

This command writes the data from the preliminary declared Long Type Array to a specified element of an IDN to a specified drive. The number of elements to write is limited by <size> parameter. This function works only for IDNs containing more than one Long Type value in array method .


<element> is optional. In general, only element 7 is used (default).

Short form

WIVALA

Syntax

WRITEIDNVALUEARRAY Drive=<drive address> IDN=<IDN number> Value=<long_type_array_name> Size=<array elements number> {Element=<IDN element number>} {Ring=<ring number>} {Connection=<connection number>}

Availability

Since Version 4.7.12 for SERCOS III

Type

<drive>: Long
<IDN number>: Long
<value>: Long Type Array name
<size>: Long
<IDN element>: Long
<ring>: Long
<connection>:Long

Range

<drive>: 1 to 254
<IDN number>: 1 to 65535
<IDN element>: 1 to 7
<size>: 1 to maximal array element number
<ring>:1
<connection>:0 to 2 for normal systems (0 = chose automatically, 1 = first AT connection, 2 = first MDT connection)

Default

<element>: 7

Scope

Configuration, Task or Terminal

Limitations

  • Write only
  • Executed only in SERCOS communication phases 2, 3 and 4
  • The IDN must be defined
  • The Long type array must be declared preliminary
  • <size> parameter must not be more than maximal number of IDN array elements
  • Not supported in EtherCAT system

Examples

Example For Bosch Rexroth drive :
-->common shared VelFilterType[10] as long 
-->WriteIdnValueArray Drive=ax1.dadd Idn=0x8000+1122 Value=VelFilterType size=4 

See Also