Difference between revisions of "MC-Basic:group.DECELERATIONSTOP"
m (Text replace - "<GROUP>" to "<''group''>") |
(AXY: new links) |
||
(10 intermediate revisions by 3 users not shown) | |||
Line 36: | Line 36: | ||
|SEE ALSO= | |SEE ALSO= | ||
− | * [[ | + | * [[MC-Basic:axis.DECELERATIONSTOP|axis.DECELERATIONSTOP]] |
− | * [[ | + | * [[MC-Basic:element.ACCELERATION|group.ACCELERATION]] |
− | * [[ | + | * [[MC-Basic:element.DECELERATION|group.DECELERATION]] |
− | * [[ | + | * [[MC-Basic:element.ACCELERATIONMAX|group.ACCELERATIONMAX]] |
+ | * [[MC-Basic:element.DECELERATIONMAX|group.DECELERATIONMAX]] | ||
}} | }} |
Latest revision as of 09:40, 13 September 2017
DecStop present the stopping deceleration in case of stop command from type DecStopOnPath. An additional use is done in internal system stopping procedure as when kill-task is operated (and slave=0 is given when conveyer tracking is on). This value is used when stop interrupts the next cases -single axis movement, or group movement from type Move or Circle.
Short form
<group>.DecStop
Syntax
<group>.DecelerationStop = <value>
Type
Double
Read/Write
Range
0.01 to Max Double
Units
Acceleration user units
Default
1000
Scope
Terminal or task
Limitations
Modal Only.
Examples
Group1.DecStop = 1000